10kVAR Detuned Series Harmonic Reactor
10kVAR Detuned Series Harmonic Reactor

10kVAR Detuned Series Harmonic Reactor

MOQ : 1 Unit

10kVAR Detuned Series Harmonic Reactor Specification

  • Low Voltage
  • 415 V AC
  • Capacity
  • 10 kVAR
  • Standard
  • IEC 60076, IS 5553
  • Cooling Type
  • Natural Air Cooling
  • Load Loss
  • Low loss, typically <2%
  • Rated Voltage
  • 415 V AC
  • Coil Material
  • Copper/Aluminum
  • Dimension (L*W*H)
  • Approx. 250 mm 180 mm 230 mm
  • Operating Temperature
  • -25C to +45C
  • Product Type
  • Detuned Series Harmonic Reactor
  • Material
  • Copper/Aluminum windings, laminated silicon steel core, epoxy resin cast
  • Output
  • Reactive Power Compensation
  • Frequency (MHz)
  • 0.05 MHz (50 Hz)
  • Efficiency
  • Above 98%
  • Phase
  • Three Phase
  • Usage
  • Harmonic mitigation in power factor correction circuits
  • Coil Structure
  • Toroidal/encapsulated
  • Coil Number
  • 3
  • Power Scope
  • 10 kVAR
  • Weight
  • Approx. 18-25 kg
  • Compliance
  • RoHS compliant materials
  • Noise Level
  • Less than 50 dB at 1 meter
  • Test Voltage
  • 2.5 kV AC for 1 min
  • Protection Class
  • IP00 (can be customized)
  • Service Life
  • 25 years under normal conditions
  • Terminals
  • Brass/Copper Terminals
  • Enclosure
  • Optional (open air standard)
  • Insulation Class
  • Class F / Class H
  • Impedance
  • 5.67% (For typical detuned applications)
  • Harmonic Suppression Range
  • Up to 5th, 7th, 11th order harmonics
  • Mounting Type
  • Base/foot mounting
 

10kVAR Detuned Series Harmonic Reactor Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 500 Units Per Month
  • Delivery Time
  • 7 Days
 

About 10kVAR Detuned Series Harmonic Reactor



Experience the acclaimed 10kVAR Detuned Series Harmonic Reactor, crafted for inestimable performance in harmonic mitigation. This lustrous reactor is ideal for power factor correction circuits, offering superior suppression of up to the 5th, 7th, and 11th order harmonics. Its wondrous efficiency, rated above 98%, and robust copper/aluminum windings encapsulated in epoxy resin guarantee an ephemeral yet powerful solution. With a 25-year service life, low noise levels, and RoHS-compliant materials, it stands as an elite offering for dependable, low-loss, and adaptable applications. Customizable protection, sturdy base mounting, and optional enclosure ensure perfect integration into your unique energy systems.

Commercial Utilisation & Diverse Application Areas

The 10kVAR Detuned Series Harmonic Reactor finds extensive commercial use in industries requiring reliable harmonic mitigation for their power factor correction circuits. Frequently employed in manufacturing plants, commercial buildings, and energy management systems, it efficiently protects sensitive equipment from harmonic distortion. Its adaptability to multiple mounting options and customizable features make it ideal for various applications such as HVAC systems, automation panels, and power distribution units-ensuring operational stability, longevity, and reduced downtime across sectors.


Prompt Delivery & Flexible Sales Options

Our acclaimed 10kVAR Detuned Series Harmonic Reactor is offered at a competitive sale price and ensures swift order processing. Shipped after thorough quality checks, reactors can usually be delivered within 7-15 business days, depending on location and customization. We accommodate requests for samples and provide swift exchange support if required. With a robust supply ability to meet large or small order volumes across India, we prioritize efficient fulfillment and hassle-free client experiences from sale to installation.


FAQ's of 10kVAR Detuned Series Harmonic Reactor:


Q: How does the 10kVAR Detuned Series Harmonic Reactor enhance power factor correction systems?

A: The reactor significantly reduces harmful harmonics, particularly up to the 5th, 7th, and 11th orders, preventing equipment overheating and voltage instability. This ultimately stabilizes power factor correction circuits and enhances overall system efficiency.

Q: What materials and design features contribute to the reactor's durability?

A: Built using copper/aluminum windings, a laminated silicon steel core, and encapsulated in epoxy resin, the reactor boasts excellent thermal management, mechanical strength, and a service life of up to 25 years under normal operating conditions.

Q: When can I expect delivery after placing an order for the reactor?

A: Delivery typically occurs within 7-15 business days after the order confirmation, ensuring you receive the product promptly and securely packed for transit.

Q: Where is the 10kVAR Detuned Series Harmonic Reactor most commonly used?

A: It is widely used in industrial plants, commercial facilities, and modern energy management systems to control harmonics and protect power-sensitive devices from electrical disturbances.

Q: What is the standard process for obtaining a product sample or initiating an exchange?

A: To request a sample or initiate an exchange, contact our sales team directly. We will guide you through the process, ensuring timely sample dispatch or product replacement as per your requirement.

Q: How does the reactor's IP00 protection class benefit users?

A: The IP00 protection class allows for open air installation and ensures flexibility for custom enclosures, making it adaptable to various onsite requirements while maintaining optimal cooling and performance.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Detuned Series Harmonic Reactor Category

5kVAR Detuned Series Harmonic Reactor

5kVAR Detuned Series Harmonic Reactor

Minimum Order Quantity : 1 Unit

Cooling Type : Natural Air Cooling

Usage : Detuned Harmonic Filtration for Power Factor Correction Panels

Phase : Three Phase

Coil Structure : Toroidal

Material : Copper/Aluminum Winding with Laminated Core

50kVAR Detuned Series Harmonic Reactor

50kVAR Detuned Series Harmonic Reactor

Minimum Order Quantity : 1 Unit

Cooling Type : Air Natural Cooled (AN).

Usage : Harmonic mitigation in power systems, detuning reactor for capacitor banks.

Phase : Other, Three Phase.

Coil Structure : Other, Threephase wound core with encapsulated coils.

Material : Copper/Aluminum winding, CRGO/EI laminated core, epoxy resinfilled.

25kVAR Detuned Series Harmonic Reactor

25kVAR Detuned Series Harmonic Reactor

Minimum Order Quantity : 1 Unit

Cooling Type : Air Cooled/Natural Convection

Usage : Harmonic filtering, Power Factor Correction

Phase : Three Phase

Coil Structure : Other, Toroidal/Epoxy resin cast, Open frame

Material : Copper/Aluminium windings with CRGO/CRNO core, epoxy resin cast

20kVAR Detuned Series Harmonic Reactor

20kVAR Detuned Series Harmonic Reactor

Minimum Order Quantity : 1 Unit

Cooling Type : Air Natural Cooled (AN)

Usage : Harmonic Filtering in Power Systems

Phase : Three Phase

Coil Structure : Other, Toroidal / Cylindrical (Encapsulated)

Material : Copper / Aluminum (as per design)



arrow